WENSUIJIA Rechargeable Veterinary Stackable Syringe Pump, Portable Single Channel Pump Machine with KVO, Alarm and Calibration

Short Description:

Easier Operation: One-key to start simple mode injection, which enables easier operation; Multi-pumps combination is allowed to save more space.
Safer Design: Audible and visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting etc.
Good Compatibility: Compatible with any syringes brand after correct calibration; Intelligently identify syringe size: 10ml, 20ml, 30ml, 50/60ml; Three levels of occlusion: high, middle and low.
Dual-CPU: Lower noise and less vibration are supported by application of motor driver IC imported from German and motor imported from Japan.
Friendly User Interface: HD LCD Display, high capacity words, , dynamically display working status.


  • Min.Order Quantity: 1000Piece/Pieces
  • Supply Ability: 50000 Piece/Pieces per Week
  • Port: Shanghai, China
  • Payment Terms: T/T
  • Product Detail

    Product Tags

    Specifications:

    Infusion Rate:
    50/60ml Syringe: 0.1ml/h~1500ml/h (0.1ml/h step)
    30ml Syringe: 0.1ml/h~900.0ml/h (0.1ml/h step)
    20ml Syringe: 0.1ml/h~600.0ml/h (0.1ml/h step)
    10ml Syringe: 0.1ml/h~300.0ml/h (0.1ml/h step)

    Rate Accuracy: Within ±3% (after correct calibration)

    Mechanical Precision: Within ±2%

    Bolus Volume :
    50/60ml Syringe: 0.1ml~10ml (0.1ml step)
    30 ml Syringe: 0.1ml~10ml (0.1ml step)
    20 ml Syringe: 0.1ml~10ml (0.1ml step)
    10 ml Syringe: 0.1ml~5ml (0.1ml step)

    Bolus Rate:
    50/60ml Syringe: 0.1ml/h~1200ml/h (0.1ml/h step)
    30 ml Syringe: 0.1ml/h~720ml/h (0.1ml/h step)
    20 ml Syringe: 0.1ml/h~480ml/h (0.1ml/h step)
    10 ml Syringe: 0.1ml/h~240ml/h (0.1ml/h step)

    Purge Rate: <br>
    50/60ml Syringe: 1500ml/h
    30ml Syringe: 900ml/h
    20ml Syringe: 600ml/h
    10ml Syringe: 300ml/h

    Total Infusion Volume: 0.1ml~9999.9ml (0.1ml step)

    Volume Limit 0.1ml~9999.9ml

    Maximum Infusion Pressure: 150kPa

    KVO Rate: 0.1ml/h~5ml/h (0.1ml/h step)

    Alarms:
    injection finish, limited finished, injection is blocked, battery empty, syringe falls off, equipment failure, syringe is improperly installed, abnormal operation, supply mains and internally powered both fail, low battery, forget the operate, injection soon finish.

    Maximum Infusion Volume (under single fault condition): 1ml

    Power Consumption: 35VA

    Power Source :
    100~240VAC, 50/60Hz;
    Internal rechargeable Li battery, capacity≥1,800mAh; voltage 11.1V, 4 hours backup time at the rate of 5ml/h for the battery charged for 12hours.
    To facilitate the use in some special occasions, the machine’s DC outlet can be an external DC 12V 2A standby power supply.

    Fuse: T2AL/250VAC, 2pcs installed

    Equipment Classification: Class I, internal power supply, Type CF

    IP Classification: IPX2

    Ambient Environment:
    Temperature: +5℃~+40℃,
    Relative humidity: 20~90%,
    Atmospheric pressure:86.0kPa~106.0kPa

    Transport & Storage Conditions:
    Temperature: -20℃~+55℃,
    Relative humidity: ≤93%,
    Atmospheric pressure:50.0kPa~106.0kPa

    Occlusion:
    High: 800mmHg±200mmHg(106.7kPa±26.7kPa)
    Medium: 500mmHg ±100mmHg (66.7kPa±13.3kPa)
    Low: 300mmHg ±100mmHg (40.0kPa±13.3kPa)

    Dimensions: 270mm (L) ×210mm (W) × 121mm (H)

    Net Weight: Approx. 2.2 kg

    Recommended Syringes: BD, SHINVA, BBRAUN

    Syringe: Compatible with any syringe brand (10ml, 20ml, 30ml, 50/60ml) after correct calibration

    Applied part: Syringe, extension tubing


  • Previous: